Cement Penetration Using a Tibial Punch Cement Pressurizer in Total Knee Arthroplasty
Abstract
abstract
This study describes a new tibial cement punch pressurizer to enhance cement penetration into the metaphyseal cancellous bone of the tibial plateau. Thirty knees of 15 patients undergoing simultaneous bilateral total knee arthroplasty (TKA) were randomly selected to receive the tibial cement punch pressurizer on one side, with the opposite side serving as control. Using computerized and radiographic evaluation of both knees 2 weeks post-operatively, the punch pressurizer achieved 1.32 times better penetration of the cement. The tibial punch cement pressurizer offers a simple technique to provide reliable cement penetration and tibial component fixation in TKA.
- 1. Ritter MA, Herbst SA. Keating EM. Faris PM. Radiolucency at the bone-cement interface in total knee replacement. The effects of bone-surface preparation and cement technique. J Bone Joint Surg Am. 1994; 76:60-65. Google Scholar
- 2. Eisler T, Svensson O, Iyer V. et al. Revision total hip arthroplasty using third-generation cementing technique. J Arthroplasty. 2000; 15:974-981. Google Scholar
- 3. Bourne RB. Oh I, Harris WH. Femoral cement pressurization during total hip arthroplasty. The role of different femoral stems with reference to stem size and shape. Clin Orthop. 1984; 183:12-16. Google Scholar
- 4. Dozier JK, Harrigan T, Kurtz WH, Hawkins C, Hill R. Does increased cement pressure produce superior femoral component fixation? J A rthroplasty. 2000; 15:488-495. Google Scholar
- 5. Noble PC, Collier MB, Maltry JA, Kamaric E. Tullos HS. Pressurization and centralization enhance the quality and reproducibility of cement mantles. Clin Orthop. 1998; 355:77-89. Google Scholar
- 6. New AM, Northmore-Ball MD, Tanner KE, Cheah SK. In vivo measurement of acetabular cement pressurization using a simple new design of cement pressurizer. J Arthroplasty. 1999; 14:854-859. Google Scholar
- 7. Bernoski FP, New AM, Scott RA, Northmore-Ball MD. An in vitro study of a new design of acetabular cement pressurizer. J Arthroplasty. 1998; 13:200-206. Google Scholar
- 8. Comell CN. Raoawat CS. The impact of modem cement techniques on acetabular fixation in cemented total hip replacement. J Arthroplasty. 1986: 1:197-202. Google Scholar
- 9. Norton MR, Eyres KS. Irrigation and suction technique to ensure reliable cement penetration for total knee arthroplasty. J Arthroplasty. 2000; 15:468-474. Google Scholar
- 10. Maistrelli GL, Antonelli L. Fornasier V. Mahomed N. Cement penetration with pulsed lavage versus syringe irrigation in total knee arthroplasty. Clin Orthop. 1995; 312:261-265. Google Scholar
- 11. Cohen J. Statistical Power Analysis far the Behavioral Sciences. 2nd ed. Hillsdale. NJ: L. Erlbaum; 1988:23-30. Google Scholar
- 12. Worland RL, Arredondo J, Angles F. LopezJimenez F, Jessup DE. Thigh pain following tourniquet application in simultaneous bilateral total knee replacement arthroplasty. J Arthroplasty. 1997; 12-.848-852. Google Scholar
- 13. Ewald CE. The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop. 1989; 248:9. Google Scholar
- 14. Davies JP, Harris WH. Ln vitro and Ln vivo studies of pressurization of femoral cement in total hip arthroplasty. J Arthroplasty. 1993;8:585-591. Google Scholar
- 15. Dunne NJ. Orr JF. Flow characteristics of curing polymethyl methacryiate bone cement. Proc Inst Mech Eng [H]. 1998; 212:199-207. Google Scholar