SMILE Procedures With Four Different Cap Thicknesses for the Correction of Myopia and Myopic Astigmatism
Abstract
PURPOSE:
To study the feasibility of performing myopic femtosecond small incision lenticule extraction (SMILE) with four different cap thicknesses (130, 140, 150, and 160 μm).
METHODS:
In this retrospective, comparative, non-randomized clinical trial, a refractive lenticule of intrastromal corneal tissue was cut with the VisuMax femtosecond laser system (Carl Zeiss Meditec AG, Jena, Germany) using different depths of the non-refractive lenticule cut. Manifest refraction, uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), and Objective Scattering Index (OSI) were evaluated. Minimum follow-up time was 1 year.
RESULTS:
Ninety-four eyes of 47 patients with myopia with (14 patients) and without (33 patients) astigmatism were treated. One year after the surgery, mean log-MAR UDVA, logMAR CDVA, SE, and OSI were 0.07 ± 0.12, 0.01 ± 0.37, 0.07 ± 0.57, and 0.88 ± 0.17, respectively (P < .05). There were no significant statistical differences in logMAR UDVA, logMAR CDVA, SE, or OSI (P > .05) variables when the different groups were compared for the same periods of time.
CONCLUSIONS:
No differences in visual acuity, refractive outcomes in optical visual quality, or complications were observed when using SMILE at four different depths.
[J Refract Surg. 2015;31(9):580–585.]
- 1.Sharma R, Vaddavalli PK. Implications and management of suction loss during refractive lenticule extraction (ReLEx). J Refract Surg. 2013; 29:502–503.
10.3928/1081597X-20130617-09 Link, Google Scholar - 2.Farjo AA, Sugar A, Schallhorn SC, Femtosecond lasers for LASIK flap creation: a report by the American Academy of Ophthalmology. Ophthalmology. 2013; 120:e5–e20.
10.1016/j.ophtha.2012.08.013 Crossref Medline, Google Scholar - 3.Shah R, Shah S, Sengupta S. Results of small incision lenticule extraction: all-in-one femtosecond laser refractive surgery. J Cataract Refract Surg. 2011; 37:127–137.
10.1016/j.jcrs.2010.07.033 Crossref Medline, Google Scholar - 4.Sekundo W, Kunert K, Russmann C, First efficacy and safety study of femtosecond lenticule extraction for the correction of myopia: six-month results. J Cataract Refract Surg. 2008; 34:1513–1520. Erratum: J Cataract Refract Surg. 2008;34:1819.
10.1016/j.jcrs.2008.05.033 Crossref Medline, Google Scholar - 5.Blum M, Kunert K, Schroder M, Sekundo W. Femtosecond lenticule extraction for the correction of myopia: preliminary 6-month results. Graefes Arch Clin Exp Ophthalmol. 2010; 248:1019–1027.
10.1007/s00417-009-1293-1 Crossref Medline, Google Scholar - 6.Ivarsen A, Hjortdal J. Correction of myopic astigmatism with small incision lenticule extraction. J Refract Surg. 2014; 30:240–247.
10.3928/1081597X-20140320-02 Link, Google Scholar - 7.Ivarsen A, Asp S, Hjortdal J. Safety and complications of more than 1,500 small-incision lenticule extraction procedures. Ophthalmology. 2014; 121:822–828.
10.1016/j.ophtha.2013.11.006 Crossref Medline, Google Scholar - 8.Sekundo W, Kunert KS, Blum M. Small incision corneal refractive surgery using the small incision lenticule extraction (SMILE) procedure for the correction of myopia and myopic astigmatism: results of a 6 month prospective study. Br J Ophthalmol. 2011; 95:335–339.
10.1136/bjo.2009.174284 Crossref Medline, Google Scholar - 9.Vestergaard A, Ivarsen A, Asp S, Hjortdal J. ReLEx smile for moderate to high myopia: a prospective study of predictability, safety and patient satisfaction. J Cataract Refract Surg. 2012; 38:2003–2010.
10.1016/j.jcrs.2012.07.021 Crossref Medline, Google Scholar